Trouble with Tamping Units and it's remedial action fault 8

Trouble with Tamping units.

You are on n4net and this is indian railway track machine trouble shooting with you.

This is a series of trouble shooting technique  for the track machine working in Indian Railway.  When you study  this you able to rectify a fault of machine. If this is helpful for you than share with others. It may helps them. Thanks for sharing.

Now we study about "Tamping Unit"
8) Fault :-  Manual lining  not functioning. .

Probable causes and Remidial action.

A)  No system pressure 
Ensure system pressure. 
B) Bye pass valve is inoperative. 
Check relay Re7 (EL.T.7002.S4) of PCB EK 349. Replace defective relay. 
C) No servo current – no deflection on galvanometer 18G2 (at position-3).  
Operate switch for manual lining.  Either X3B or X3C should come on programme panel.  
   If still no current, check Re5 for left side and Re6 for right side movement on PCB EK349.  If defective, replace relays. 