Friday, 15 February 2019

Trouble with Tamping Units and it's remedial action fault 7

Trouble with Tamping units.

You are on n4net and this is indian railway track machine trouble shooting with you.

This is a series of trouble shooting technique  for the track machine working in Indian Railway.  When you study  this you able to rectify a fault of machine. If this is helpful for you than share with others. It may helps them. Thanks for sharing.

Now we study about "Tamping Unit"
7) Fault :-  Satellite movement reverse failed.

Probable causes and Remidial action.

A) No  proportional current. 
1. Check output QL.36  
If signal is OK check relay QL.36 (ELT.7002.S4 of B7 Panel). 
    Replace defective relay. 
2.  If no signal at QL36 –  
Check input signal X34 for satellite reverse by joystick. 
3. Signal 0B should not come.  If signal 0B comes, check position of tamping unit middle or upper position. 

No comments:

What is the General safety on track machine

General safety rules followed by track machine staffs You are on n4net and this is indian railway track machine trouble shooting technology ...