Trouble with Tamping units.
You are on n4net and this is indian railway track machine trouble shooting with you.
This is a series of trouble shooting technique for the track machine working in Indian Railway. When you study this you able to rectify a fault of machine. If this is helpful for you than share with others. It may helps them. Thanks for sharing.
Now we study about "Tamping Unit"5) Fault :- Machine not moving in reverese direction.
Probable causes and Remidial action.
A) No deflection on galvanometer 18G2 of programme panel switch on position-4.Check signal Q09 - X 09. If no signal.- Check X37 or X 38 switch and signal X37 or X38 on programme panel.
- Check input signal X23 for reverse joystick.
- Check input signal X13 and X14 indicating tamping unit is in middle or Up position.
- Output signal Q83, indicates that machine moving in reverse direction.
- No signal X30 indicates, auto working switch is off.
- Check out put signal Q42. If Q42 is OK, check relay 18U1(C) (EL.T.277). Replace defective relay.
- Check relay QL37 (EL.T.7002.S4) behind B7 panel. Replace defective relay.
If all the above conditions are OK, replace PCB EK319.
You are on n4net and this is indian railway track machine trouble shooting with you.
This is a series of trouble shooting technique for the track machine working in Indian Railway. When you study this you able to rectify a fault of machine. If this is helpful for you than share with others. It may helps them. Thanks for sharing.
Now we study about "Tamping Unit"
5) Fault :- Machine not moving in reverese direction.
Probable causes and Remidial action.
A) No deflection on galvanometer 18G2 of programme panel switch on position-4.
Check signal Q09 - X 09. If no signal.
- Check X37 or X 38 switch and signal X37 or X38 on programme panel.
- Check input signal X23 for reverse joystick.
- Check input signal X13 and X14 indicating tamping unit is in middle or Up position.
- Output signal Q83, indicates that machine moving in reverse direction.
- No signal X30 indicates, auto working switch is off.
- Check out put signal Q42. If Q42 is OK, check relay 18U1(C) (EL.T.277). Replace defective relay.
- Check relay QL37 (EL.T.7002.S4) behind B7 panel. Replace defective relay.
If all the above conditions are OK, replace PCB EK319.