Trouble in engine and it's remedial action Fault 10

Trouble in engine which damaged parts.

You are on n4net and this is indian railway track machine trouble shooting with you.

This is a series of trouble shooting technique   for the track machine working in indian Railways. When you study with this you able to rectify a fault of machine. If this is helpful for you than share with others. It may helps them. Thanks in advance for sharing.

Now first we start with engine model number
 TBD 232V12

10) fault:- Engine speed is irregular.

Probable cause and remedial action
A) Air in the fuel system.
Bleed air from fuel system in the following steps:-
a) loosen the bleed plug on the fuel filter and operate the priming pump until the fuel emerge of bubbles tighten the bleed plug.
b) The loosen banjo on injector pump and operate priming pump until fuel emerged free of bubbles. Tighten the banjo plug.
G)  Governor is stuck.
Call the service engineer. Governor needs repair.