2) Fault :-  Fails to completely unload pump. 

Probable causes and Remidial action.

1.  Valve pressure setting too high. 
>> Set valve at proper pressure. 
2.  Valve  spool  binding  in body. 
>>  Clean the spool and oil in the tank. 
3.  Incorrect assembly. 
>>  Assemble as per proper drawing. 
4.  Nil   or  low   nitrogen pressure in the accumulator. 
>>   Check pressure and recharge the accumulator    ( 80 to 85 bar). 
5.  Punctured bladder. 
>>   Change the bladder. 